Onshore/Offshore Service Modules - The Hazardous Area Experts

Custody Metering House and Analyser House


A vital function of metering is to identify the exact flow through the pipes. CAPESERVE’s Custody Metering House (CMH) and Analyser House (ANG) provide controlled environment from external factors that may affect the readings of the analysis as well as provide a safe work space for both personnel and equipment.

CAPESERVE’s team of experts design, develop, engineer and manufacture Custody Metering House (CMH) and Analyser House (ANH) with consideration of local ambient conditions, hazardous area classification, sample type, analyser type together with project specifications. We ensure the houses are robust, fully tested and provide our clients a controlled environment to house their analysis equipment providing a fully integrated turn-key solution for ease of installation in the petrochemical plants.


TALK TO OUR TECHNICAL SALES TEAMGET A QUOTE



Features & Specification

Features

  • Safe Area Operation / Zone 1 IIB T3 Hazardous Area Operation / Zone 2 IIB T3 Hazardous Area Operation
  • ATEX / IECEx compliance at component level
  • Stacking Capability with ISO Twist locks for economy of deck space
  • Pressurized solution with positive cabin pressure for Safe area operation inside cabin
  • Complete with HVAC system suitable safe area / Zone 1 IIB T3 / Zone 2 IIB T3
  • Combine Pressurization Fire and Gas Safety system
  • Passive Insulation SOLAS A60 / H120 rated conforms to the latest FTP codes
  • Internal fit out requirement as customized to suit project requirements
  • Airlock System (For Zone 1 unit only

Dimension

The Custody Metering House and Analyzer Shelter can range from skid mounted system or cabinets to prefabricated buildings and portable cabins. Sizes can be standard offshore / onshore container size or customised to suit any specific project and space requirements

Certification Body

  • DNV GL ST E271 (earlier DNV2.7-1) Certified Enclosure & Certified Slings by DNV GL or Lloyds Register (LR)
  • LR (Convention of Safe Container). Unit may be shipped as standard container. (Optional)

Optional

  • DNV GL ST E272 (earlier DNV2.7-2) Certification
  • Blast Resistant Modules certification as per API RP 753 and 752
  • Zone 1 / Zone 2 Compliance Certificate from Third Party (optional)
  • GOST R
  • Compliance to NFPA 496
  • ATEX & CE Marking Complete Assembly Certification from Notifying Body
  • CO2 Fire suppression system

Application

  • Custody Metering House (CMH)
  • Analyzer Shelter (ANH)

CONTACT US


MALAYSIA

CAPESERVE ENERGY SDN. BHD. [201701019125 (1233290-M)]
D-06-05, Block D, Level 6,
Sky Park, One City, Jalan USJ 25/1,
47650 Subang Jaya, Selangor, Malaysia.

+603 8604 8677


SINGAPORE

CAPES ENGINEERING PTE. LTD.
100 Peck Seah Street #08-14 PS100
S079333.

+ 65 96688273

DUBAI

Capeserve ME FZCO
Office no:142, DTEC Technohub
Dubai Silicon Oasis
Dubai, UAE


sales@capeserve.com

training@capeserve.com


Copyright © 2023.
All Rights Reserved.



Website by Kumbang CX Inspirations